辻村 憲雄; 高橋 史明; 高田 千恵
Progress in Nuclear Science and Technology (Internet), 6, p.148 - 151, 2019/01
Criticality accident neutron dosimetry is based on measurement of the personal dosemeter and the biological samples of a person exposed to the neutrons from an accidental criticality. The authors computed the response functions of the personal dosemeter (NCL-TLD badge) and hair (sulfur) activation per unit incident neutron fluence and established the response dataset compiled with the 140 neutron spectra to be likely encountered in a criticality accident.